< PreviousSuperior Reliability & Performance 18 StingRay and BioRay Life Sciences Guide StingRay/BioRay Standard StingRay Mechanical Specifications 1 StingRay in Mount, BioRayMechanical Specifications 1 STEP 1: Choose your package with optional separated electronics, mounts, and/or fiber attachment. Choose only one option from the following selections. Ø 19.1 mm (0.75 in.) 95.0 mm (3.74 in.) 27.0 mm (1.06 in.) 36.0 mm (1.42 in.) Clamping Area Beam Exit Focus Status LED 13.0 mm (0.50 in.) Add 50 mm (1.97 in.) for Cable Bend Radius 50.8 mm (2.0 in.) 95.0 mm (3.74 in.) 70.0 mm (2.76 in.) 19.1 mm (0.75 in.) 40.0 mm (1.57 in.) 14.4 mm (0.57 in.) 9.0 mm (0.35 in.) 15.5 mm (0.61 in.) 34.0 mm (1.34 in.) 32.0 mm (1.26 in.) 31.4 mm (1.24 in.) OBIS Adapter 2 Piece Laser Mount Laser Mount 1 For more dimension details and CAD drawings, please visit www.coherent.comcoherent.com 19 Life Sciences Guide StingRay and BioRay StingRay/BioRay Separate Driver, Compact Laser Head Mechanical Specifications 1 BioRay FR (Fiber-Ready with SMA)Mechanical Specifications 1 STEP 1 (continued): (select cable length between laser head and driver) 75 mm 150 mm 250 mm 500 mm Driver Laser Head 50.8 mm (2.0 in.) 100.0 mm (3.94 in.) 70.0 mm (2.76 in.) 19.1 mm (0.75 in.) 40.0 mm (1.57 in.) 14.4 mm (0.57 in.) 9.0 mm (0.35 in.) 15.5 mm (0.61 in.) 39.0 mm (1.54 in.) 37.0 mm (1.46 in.) 31.4 mm (1.24 in.) OBIS Adapter 2 Piece Laser Mount Laser Mount SMA 53.1 mm (2.09 in.) 21.6 mm (0.85 in.) Ø 19.1 mm (0.75 in.) Clamping Surface Ø 19.1 mm (0.75 in.) 68.0 mm (2.68 in.) 36.0 mm (1.42 in.) Clamping Area Status LED 1 For more dimension details and CAD drawings, please visit www.coherent.comSuperior Reliability & Performance 20 StingRay and BioRay Life Sciences Guide StingRay/BioRay Wavelength Choices 1 (nm) Wavelength Choices 1 (nm) Output Power Available (mW) 1 5 10 20 25 35 50 75 90 100 150 200 STEP 2: Choose your wavelength. Choose only one of the following selections. STEP 3: Choose your power. Choose only one of the following selections. 405 450 488 520 525 639 640 655 660 685 785 830 405 450 488 520 525 639 640 655 660 685 785 830 1 BioRay FR available in 405 nm, 450 nm, 488 nm and 640 nm. StingRay and BioRay Laser-to-laser wavelength tolerance of 405 nm is ±5 nm, 450 nm is ±10 nm, 488 nm is ±10 nm, 520 nm is 510 nm to 530 nm, 525 nm is 520 nm to 530 nm, 639 nm is 635 nm to 648 nm, 640 nm is ±6 nm, 647 nm is ±5 nm, 655 nm is 650 nm to 665 nm, 660 nm for ≥50 mW is 655 to 665 nm, 660 nm for <50 mW is 652 to 662 nm, 685 is ±15 nm, 785 nm is ±19 nm, 830 nm is 815 nm to 840 nm. 1 BioRay FR (Fiber-Ready) only available in 405 nm 50 mW, 450 nm 50 mW, 488 nm 20 mW and 640 nm 40 mW. BioRay FR offers >70% coupling efficiency with NA=0.22 into a customer-provided 50 µm or 100 µm fiber.coherent.com 21 Life Sciences Guide StingRay and BioRay StingRay/BioRay CW Mode Function Continuous Wave (CW) Constant power mode Laser on at full power User can adjust laser output power and monitor power through RS-232 option (if enabled) No modulation input required Analog Modulation 1 Function Analog (A) Input <0.5V = output power is off, Input = 5V is 100% output power, 0.5V to 5V is linear power control from external voltage source Bandwidth of 500 kHz Rise time (10% to 90%) <1 µsec, 500 nsec (typ.) Fall time (90% to 10%) <1 µsec, 500 nsec (typ.) Analog Modulation can be used with a DC voltage input to simply vary the output power Reverse Analog (RA) Input >4.5V = output power is off, Input = 0V is 100% output power, 4.5V to 0V is linear power control from external voltage source Bandwidth of 500 kHz Rise time (10% to 90%) <1 µsec, 500 nsec (typ.) Fall time (90% to 10%) <1 µsec, 500 nsec (typ.) Reverse Analog Modulation can be used with a DC voltage input to simply vary the output power STEP 4: Choose your output power control: CW, analog modulation (variable output power), or digital modulation. Choose only one of the following selections. 1 BioRay is standard with Analog Modulation and will require a 5V input signal to operate. Input Voltage (V) Laser Output Power (%) 0 10 20 30 40 50 60 70 80 90 100 00.51.01.52.02.53.03.54.04.55.0 Input Voltage (V) Laser Output Power (%) 0 10 20 30 40 50 60 70 80 90 100 00.51.01.52.02.53.03.54.04.55.0 No adjustable output power through RS-232 No adjustable output power through RS-232Superior Reliability & Performance 22 STEP 4 (continued): Digital Modulation Function Digital TTL (T) Fast Digital TTL (FT) Input 0V to 1V is output power off, Input 4V to 5V is 100% output power Maximum bandwidth of 100 KHz Rise time (10% to 90%) <1 msec Fall time (90% to 10%) <1 msec Maximum bandwidth of 2 MHz Rise time (10% to 90%) <150 nsec Fall time (90% to 10%) <150 nsec Reverse Digital TTL (RT) Reverse Fast Digital TTL (RFT) Input 0V to 1V is 100% output power, Input 4V to 5V is 0% output power Maximum bandwidth of 100 KHz Rise time (10% to 90%) <1 msec Fall time (90% to 10%) <1 msec Maximum bandwidth of 2 MHz Rise time (10% to 90%) <150 nsec Fall time (90% to 10%) <150 nsec (RS-232 Set Power) 0 10 20 30 40 50 60 70 80 90 100 Input Voltage (V) 00.51.01.52.02.53.03.54.04.55.0 Laser Output Power (%) (RS-232 Set Power) 0 10 20 30 40 50 60 70 80 90 100 Input Voltage (V) 00.51.01.52.02.53.03.54.04.55.0 Laser Output Power (%) User can adjust output power setting through RS-232 option (if enabled) User can adjust output power setting through RS-232 option (if enabled) StingRay and BioRay Life Sciences Guide StingRay/BioRaycoherent.com 23 Life Sciences Guide StingRay and BioRay StingRay/BioRay Elliptical Dot Beam D01 – Coherent’s high-quality elliptical collimated beam with user adjustable focus to change the beam divergence. D01-XX, Standard ~1 mm by ~3 mm beam diameter MicoFocus µFL D01 – Coherent’s high-quality elliptical collimated beam with user adjustable focus to change the beam divergence. Large diameter beam allows for tighter focus spots. µFL D01-XX, Large beam diameter 2X with less divergence Line Beam Generator L01 – Coherent’s Premier Flat-Top Line Technology, with nine choices for the fan angle at which the line expands out from the laser. L01-1 Line with 1 degree fan angle Fan angle 1⁰ with tolerance ±10% Relative intensity floor >75% Contained Power ≥90% Note: Not available in 488 nm L01-5 Line with 5 degree fan angle Fan angle 5⁰ with tolerance ±10% Straightness <0.1% Relative intensity floor >75% Contained Power ≥95% Note: Not available in 488 nm STEP 5: Choose your beam shape. Choose only one of the following selections.Superior Reliability & Performance 24 StingRay and BioRay Life Sciences Guide StingRay/BioRay STEP 5 (continued): Line Beam Generator (cont.) L01-10 Line with 10 degree fan angle Fan angle 10⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >75% Contained Power ≥95% Note: Not available in 488 nm L01-15 Line with 15 degree fan angle Fan angle 15⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >75% Contained Power ≥95% Note: Not available in 488 nm L01-20 Line with 20 degree fan angle Fan angle 20⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >75% Contained Power ≥95% Note: Only available for wavelengths 520 nm to 785 nm L01-30 Line with 30 degree fan angle L01-30 Line with 30 degree fan angle, micro-focus (µFL) Fan angle 30⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >75% Contained Power ≥95% Note: Not available in 488 nm. Micro-focus (µFL) only available in 520 nm to 785 nm.coherent.com 25 Life Sciences Guide StingRay and BioRay StingRay/BioRay STEP 5 (continued): GLOSSARY OF TERMS: DefinitionDescription Fan Angle or Line Length Length of flat top profile, measured at 80% intensity clip levels. Reported in degrees for the fan angle. Straightness Maximum deviation from the best fit line. Measured as the delta from the best fit line divided by the line length. Reported as a percentage. Relative Intensity Floor Minimum relative intensity at any point along the line length. Reported as a relative intensity. Contained Power Power contained within the defined Flat Top. Position Normalized Intensity (%) 0 100 20 40 60 80 Fan Angle (Line Length) measured at 80% Relative Intensity Contained Power: power contained within the area of the fan angle above, and the width of the line at 1/e2 Profile will not drop below the “Relative Intensity Floor” Note: Line is optimized in the factory at 500 mm working distance from laser Line Beam Generator (cont.) L01-45 Line with 45 degree fan angle L01-45 Line with 45 degree fan angle, micro-focus (µFL) Fan angle 45⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >60% Contained Power ≥95% Note: Not available in 488 nm. Micro-focus (µFL) only available in 520 nm to 785 nm. L01-60 Line with 60 degree fan angle L01-60 Line with 60 degree fan angle, micro-focus (µFL) Fan angle 60⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >60% Contained Power ≥95% Note: Not available in 488 nm. Micro-focus (µFL) only available in 520 nm to 785 nm. L01-75 Line with 75 degree fan angle Fan angle 75⁰ with tolerance ±5% Straightness <0.1% Relative intensity floor >50% Contained Power ≥95% Note: Not available in 488 nmSuperior Reliability & Performance 26 StingRay and BioRay Life Sciences Guide StingRay/BioRay FocusDescription Standard, Default, 500 mm Adjustable focus feature factory set for best focus at 500 mm distance from laser. You can readjust and lock as needed. Custom, _________ mm Choose from a 50 mm up to a 2000 mm focus distance. Adjustable focus feature factory set to your specified distance from laser. You can readjust and lock as needed. Choosing 2000 mm is “collimated”. FocusDescription None No communications. RS-232 disabled. RS-232 RS-232 enabled for laser control and status. Can monitor hours, power and temperature. Can adjust laser output power for CW and digital modulation modes. STEP 6: Choose your focus distance (Coherent can preset the adjustable focus). Choose only one of the following selections. STEP 7: Choose your communication option (RS-232). Choose only one option of following selections.coherent.com 27 Life Sciences Guide StingRay and BioRay StingRay/BioRay STEP 8: Choose your cable length and connector/pinout. Choose only one of the following selections. CodeDescriptionImageConnection FLFlying Leads Choose Length (mm) 250 500 1000 1500 2000 2500 V in V in Ground Fault V mod V mod Ground RS-232 Transmit RS-232 Receive RS-232 Ground Red Black Green Blue Red/Black Orange White White/Black HRHirose R10A-10P-12SC(73) 1000 mm V in V in Ground Fault V mod V mod Ground RS-232 Transmit RS-232 Receive RS-232 Ground 9 1 10 2 3 6 4 5 PPower Plug, Phono 3.5 mm 500 mm Note: Only for CW mode V in V in Ground, Shield Fault V mod V mod Ground RS-232 Transmit RS-232 Receive RS-232 Ground Tip Base No Connection No Connection No Connection No Connection No Connection No Connection BPower Plug, Phono 3.5 mm and BNC for Modulation 500 mm Note: Do not order with CW mode V in V in Ground, Shield Fault V mod V mod Ground RS-232 Transmit RS-232 Receive RS-232 Ground Phono Plug Tip Phono Plug Base No Connection BNC Tip BNC Base No Connection No Connection No Connection PP ;675,33('$1' 7,11('$:*:,5( )/<,1*/($'6 PP PP +,526( 127&+ PP PP PP PP 9LQ*1' 9LQ 3+21232:(53/8* PP PP PP PP PP PP 9PRG 9PRG*1' 9LQ*1' 9LQ 3+21232:(53/8*:,7+%1&Next >