< PreviousSuperior Reliability & Performance 88 SPECIFICATIONS 1 Genesis MX-460 Genesis MX-480 Genesis MX-488 Genesis MX-514 Wavelength (nm) 460 ±3 480 ±3488 ±3514 ±3 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 1000, 200020003000, 50003000, 5000 Spatial Mode Multimode Beam Quality (M 2 ) Horizontal Vertical <7 <7 Beam Circularity 2,3,4 1.25 Beam Waist Diameter 2,4 (mm) (FW, 1/e 2 )1.41.61.61.8 Beam Divergence 2,4 (mrad) (FW, 1/e 2 ) 1.31.51.5<1.4 Beam Waist Location 2,4,5 (mm) 0.25 ±0.25 Beam Pointing Stability 2,6 (μrad/°C) <5 Horizontal Beam Position Tolerance 7 (mm) ±<1.0 Vertical Beam Position Tolerance 7 (mm) ±<1.0 Beam Pointing Tolerance 7 (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Vertical, ±5° Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz (%) (pk-pk) <1 <10 Power Stability 8 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes ELECTRICAL SPECIFICATIONS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Non-Operating 10 to 40°C (50 to 104°F) water-cooled, 10 to 35°C (50 to 95°F) air-cooled -10 to 60°C (14 to 140°F) Relative Humidity 9 (%) 5 to 95 CE MarkingIEC 61010-1/EN 61010-1 Dimensions (L x W x H) Laser Head 10 Cables (laser head to controller) 281 x 156 x 85 mm (11.06 x 6.14 x 3.35 in.) 2 m (6.5 ft.) 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Contact Coherent for any specific application requirements. 3 Circularity defined as vertical diameter divided by horizontal diameter. 4 Typical value. 5 Negative value corresponds to a location inside head. 6 After 2-hour warm-up. 7 Measured at the output window. 8 Measured over 8 hrs. 9 Non-condensing. 10 Back connector not included in laser head length dimension. Genesis MX MTM-Series Life Sciences Guide Genesis MXcoherent.com 89 SPECIFICATIONS 1 Genesis MX-532 Genesis MX-561 Genesis MX-577 Genesis MX-590 Wavelength (nm) 532 ±3 561 ±3577 ±3590 ±3 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 3000, 5000, 800020003000, 50001000, 2000 Spatial Mode Multimode Beam Quality (M 2 ) Horizontal Vertical <7 <7 Beam Circularity 2,3,4 1.25 Beam Waist Diameter 2,4 (mm) (FW, 1/e 2 )1.8 Beam Divergence 2,4 (mrad) (FW, 1/e 2 ) <1.4 Beam Waist Location 2,4,5 (mm) 0.25 ±0.25 Beam Pointing Stability 2,6 (μrad/°C) <5 Horizontal Beam Position Tolerance 7 (mm) ±<1.0 Vertical Beam Position Tolerance 7 (mm) ±<1.0 Beam Pointing Tolerance 7 (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Vertical, ±5° Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz (%) (pk-pk) <1 <10 Power Stability 8 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes ELECTRICAL SPECIFICATIONS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Non-Operating 10 to 40°C (50 to 104°F) water-cooled, 10 to 35°C (50 to 95°F) air-cooled -10 to 60°C (14 to 140°F) Relative Humidity 9 (%) 5 to 95 CE MarkingIEC 61010-1/EN 61010-1 Dimensions (L x W x H) Laser Head 10 Cables (laser head to controller) 281 x 156 x 85 mm (11.06 x 6.14 x 3.35 in.) 2 m (6.5 ft.) 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Contact Coherent for any specific application requirements. 3 Circularity defined as vertical diameter divided by horizontal diameter. 4 Typical value. 5 Negative value corresponds to a location inside head. 6 After 2-hour warm-up. 7 Measured at the output window. 8 Measured over 8 hrs. 9 Non-condensing. 10 Back connector not included in laser head length dimension. Life Sciences Guide Genesis MX MTM-Series Genesis MXSuperior Reliability & Performance 90 SPECIFICATIONS 1 Genesis MX-920 Genesis MX-1064 Genesis MX-1154 Wavelength (nm) 920 ±101064 ±101154 ±15 Output Power (mW) 400010,0006000 Spatial Mode Multimode Bandwidth (nm)<5.0 Beam Waist Dimensions Horizontal 2 (FW, 1/e 2 , mm) Vertical 2 (FW, 1/e2, mm) Location 2,3 (mm) 0.6 0.6 -150 Beam Divergence Horizontal 4 (FW, 1/e 2 , mrad) Vertical 4 (FW, 1/e 2 , mrad) 3.5 3.5 M2 Horizontal Vertical <3 <3 Beam Pointing Stability 4 (μrad/°C) <5 Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz (%) (pk-pk) <0.5 <10 Polarization Ratio Vertical, >100:1 UTILITY AND ENVIRONMENTAL REQUIREMENTS Operating Diode Current (A) <30<38<32 Maximum Diode Current (A) <36<45<38.5 Diode Voltage (V) 500 Cooling Requirements 5 Active cooling required Case Temperature (°C) 25 ±2 Humidity Non-condensing Dimensions (L x W x H) Laser Head 5 256 x 49 x 71 mm (10.07 x 1.93 x 2.76 in.) Weight Laser Head (g)730 ±10 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Typical value. 3 Measured from the output face, negative value corresponds to a location inside the head; positive outside. 4 Measured at the output window: tolerance relative to the nominal center of the output window and perpendicular to the mounting plane. 5 Contact integration support for options on air-cooling TEC or waterplate. Genesis MX MTM-Series Life Sciences Guide Genesis MXcoherent.com 91 SPECIFICATIONS 1 Genesis MX 460 OEM Genesis MX 480 OEM Genesis MX 488 OEM Genesis MX 514 OEM Wavelength (nm) 460 ±3480 ±3488 ±3514 ±3 Output Power (mW) 1000, 200020003000, 50003000, 5000 Spatial Mode Multimode Bandwidth (nm)<5.0 Beam Waist Dimensions Horizontal 2 (FW, 1/e 2 , mm) Vertical 2 (FW, 1/e2, mm) Location 2,3 (mm) 0.14 0.11 -60 0.17 0.13 -60 0.17 0.16 -60 0.17 0.13 -60 Beam Divergence Horizontal 2 (FW, 1/e 2 , mrad) Vertical 2 (FW, 1/e 2 , mrad) <18 <16 <20 <20 <20 <20 <20 <20 Collimated Version Beam Waist Diameter 2 (1/e2, mm) Beam Divergence 2 (1/e 2 , mrad) Beam Waist Location 2 (m) 1.4 1.3 0.25 ±0.25 1.6 1.5 0.25 ±0.25 1.6 1.5 0.25 ±0.25 1.8 1.4 0.25 ±0.25 M 2 Horizontal Vertical <7 <7 Beam Pointing Stability 4 (μrad/°C) <5 Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz (%) (pk-pk) <1 <10 Polarization RatioHorizontal, >100:1 Direct Modulation 5 Available UTILITY AND ENVIRONMENTAL REQUIREMENTS Operating Diode Current (A) <22.5, <27 <27 <30, <33 <30, <33 Maximum Diode Current (A) <27, <32 <32<36, <40<36, <40 Diode Voltage (V) 1.5 to 2.2 Cooling Requirements 6 Active cooling required Case Temperature (°C) 25 ±2 Humidity Non-condensing Dimensions (L x W x H) Laser Head 5 121 x 44 x 65 mm (4.76 x 1.73 x 2.56 in.) Weight Laser Head (g)730 ±10 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Typical value. 3 Measured from the output face, negative value corresponds to a location inside the head; positive outside. 4 Measured at the output window: tolerance relative to the nominal center of the output window and perpendicular to the mounting plane. 5 Theoretical limit is >1 MHz; actual performance will be limited by the diode-driver (not included). 6 Contact integration support for options on air-cooling TEC or waterplate. Life Sciences Guide Genesis MX MTM-Series Genesis MXSuperior Reliability & Performance 92 SPECIFICATIONS 1 Genesis MX 532 OEM Genesis MX 561 OEM Genesis MX 577 OEM Genesis MX 590 OEM Wavelength (nm) 532 ±3561 ±3577 ±3590 ±3 Output Power (mW) 3000, 5000, 800020003000, 50001000, 2000 Spatial Mode Multimode Bandwidth (nm)<0.5 Beam Waist Dimensions Horizontal 2 (FW, 1/e 2 , mm) Vertical 2 (FW, 1/e2, mm) Location 2,3 (mm) 0.17 0.13 -60 0.17 0.13 -60 0.13 0.13 -60 0.13 0.13 -60 Beam Divergence Horizontal 2 (FW, 1/e 2 , mrad) Vertical 2 (FW, 1/e 2 , mrad) <20 <20 Collimated Version Beam Waist Diameter 2 (1/e2, mm) Beam Divergence 2 (1/e 2 , mrad) Beam Waist Location 2 (m) 1.8 1.4 0.25 ±0.25 M 2 Horizontal Vertical <7 <7 Beam Pointing Stability 4 (μrad/°C) <5 Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz (%) (pk-pk) <1 <10 Polarization RatioHorizontal, >100:1 Direct Modulation 5 Available UTILITY AND ENVIRONMENTAL REQUIREMENTS Operating Diode Current (A) <30, <33, <38<33 <30, <33 <30, <32 Maximum Diode Current (A) <36, <40, <45 <40<36, <40<36, <38 Diode Voltage (V) 1.5 to 2.2 Cooling Requirements 6 Active cooling required Case Temperature (°C) 25 ±2 Humidity Non-condensing Dimensions (L x W x H) Laser Head 5 121 x 44 x 65 mm (4.76 x 1.73 x 2.56 in.) Weight Laser Head (g)730 ±10 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Typical value. 3 Measured from the output face, negative value corresponds to a location inside the head; positive outside. 4 Measured at the output window: tolerance relative to the nominal center of the output window and perpendicular to the mounting plane. 5 Theoretical limit is >1 MHz; actual performance will be limited by the diode-driver (not included). 6 Contact integration support for options on air-cooling TEC or waterplate. Genesis MX MTM-Series Life Sciences Guide Genesis MXcoherent.com 93 MECHANICAL SPECIFICATIONS Genesis MX MTM-Series (End-User) Air-cooled version Genesis MX MTM-Series (End-User) Water-cooled version 119.08 mm (4.69 in.) 67.34 mm (2.65 in.) 61.6 mm (2.43 in.) 246.08 mm (9.69 in.) 265.13 mm (10.44 in.) 13.53 mm (0.53 in.) 10.41 mm (0.41 in.) 10.0 mm (0.39 in.) 0.0 mm(0.0 in.) 59.56 mm (2.34 in.) 76.56 mm (3.01 in.)188.56 mm (7.42 in.) 205.56 mm (8.09 in.) Mounting Holes M5 - 0.8 X 0.38 in. Deep (4X) Mounting Holes 10-32 X 0.38 in. Deep (4X) Alignment Slot 0.251/0.252 in. Wide X 0.25 in. Long X 0.38 in. Deep Alignment Hole 0.251/0.252 in. Dia. X 0.38 in. Deep 61.6 mm (2.43 in.) 65.0 mm (2.56 in.) 45.0 mm (1.77 in.) 10-32 M5 M5 M5 M5 10-32 10-32 10-32 68.2 mm (2.69 in.) 47.63 mm (1.88 in.) 95.25 mm (3.75 in.) Front View Top View Side View Rear View 119.08 mm (4.69 in.) 61.6 mm (2.43 in.) 246.08 mm (9.69 in.) 265.13 mm (10.44 in.) 21.29 mm (0.84 in.) 13.53 mm (0.53 in.) 10.41 mm (0.41 in.) 10.0 mm (0.39 in.) 0.0 mm(0.0 in.) 59.56 mm (2.34 in.) 76.56 mm (3.01 in.)188.56 mm (7.42 in.) 205.56 mm (8.09 in.) Mounting Holes M5 - 0.8 X 0.38 in. Deep (4X) Mounting Holes 10-32 X 0.38 in. Deep (4X) Alignment Slot 0.251/0.252 in. Wide X 0.25 in. Long X 0.38 in. Deep Alignment Hole 0.251/0.252 in. Dia. X 0.38 in. Deep 61.6 mm (2.43 in.) 65.0 mm (2.56 in.) 45.0 mm (1.77 in.) 10-32 M5 M5 M5 M5 10-32 10-32 10-32 68.2 mm (2.69 in.) 47.63 mm (1.88 in.) 95.25 mm (3.75 in.) Front View Top View Side View Rear View Life Sciences Guide Genesis MX MTM-Series Genesis MXSuperior Reliability & Performance 94 MECHANICAL SPECIFICATIONS 19.05 mm (0.75 in.) 5.46 mm (0.22 in.) 18.8 mm (0.74 in.) 18.8 mm (0.74 in.) 24.89 mm (0.98 in.) 6.1 mm (0.24 in.) 5.08 mm (0.2 in.) 45.21 mm (1.78 in.) 6.35 mm (0.25 in.) 6.35 mm (0.25 in.) 6.35 mm (0.25 in.) 5.08 mm (0.2 in.) 16.26 mm (0.64 in.) Spacer Detail Clamping Bar Detail 3.175 mm (0.125 in.) 1.52 mm (0.06 in.) 12.95 mm (0.51 in.) 4.06 mm (0.16 in.) 86.87 mm (3.42 in.) 89.92 mm (3.54 in.) 112.78 mm (4.44 in.) 112.78 mm (4.44 in.) 120.65 mm (4.75 in.) 11.43 mm (0.45 in.) 53.59 mm (2.11 in.) 12.7 mm (0.5 in.) 15.24 mm (0.6 in.) 50.39 mm (1.98 in.) 64.47 mm (2.54 in.) 27.94 mm (1.1 in.) 19.05 mm (0.75 in.) 29.78 mm (1.17 in.) 4-40 UNC-2B X 0.25 Deep Tapped Holes (4X) 4-40 UNC-2B X 0.20 Deep (2X) Window 8-32 UNC-2B X 0.50 Deep (4X) 0.125 Dia. Dowel Pin (2X) 0.188 Dia. Thru (2X) This surface must be flat within 0.001 in. and have 32 µm finish or better within TEC mounting areas. 9.53 mm (0.375 in.) 9.53 mm (0.375 in.) 44 mm (1.73 in.) 120.65 mm (4.75 in.) 111.1 mm (4.37 in.) 4.78 mm (0.19 in.) 7.9 mm (0.31 in.) 3.13 mm (0.12 in.) Ø15.88 mm (0.625 in.) 13.49 mm (0.53 in.) 13.51 mm (0.53 in.) 2° 22 mm (0.87 in.) Base Plate Requirements Front View Top View Side View Rear View Genesis MX MTM-Series (OEM) Genesis MX MTM-Series Life Sciences Guide Genesis MXcoherent.com 95 MECHANICAL SPECIFICATIONS Genesis MX-Series Heat Sink Genesis MX MTM-Series Benchtop Power Supply 159.8 mm (6.29 in.) 19.8 mm (0.78 in.) 361.1 mm (14.22 in.) 228.9 mm (9.01 in.) Side ViewFront View OPS Head Mounted on Heat SinkHeat Sink with Thermoelectric Coolers Installed Heat Sink Top Features Life Sciences Guide Genesis MX MTM-Series Genesis MXSuperior Reliability & Performance 96 MECHANICAL SPECIFICATIONS 208.28 mm (8.2 in.) 96.52 mm (3.8 in.) 299.72 mm (11.8 in.) Front ViewRear View Top View Side View Bottom View Genesis MX MTM-Series OEM Benchtop Power Supply Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Genesis MX MTM lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative. ISO 9001 Registered Genesis MX MTM-Series Life Sciences Guide Genesis MXcoherent.com 97 Genesis MX Genesis MX STM-Series TEM 00 Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers. The Genesis MX STM-Series provides up to 1 W of visible laser light from either OEM or CDRH-compliant end-user systems. Based on Coherent’s unique Optically Pumped Semiconductor Laser (OPSL) technology, the Genesis MX STM-Series features variable output power without changing the beam parameters. This, combined with a diffraction-limited beam, low noise and high stability, provides unparal- leled laser performance in a convenient package. Genesis MX STM-Series is the perfect match for customers in need of the highest performing CW laser technology for research and instrumen- tation in life science and biological applications. FEATURES & BENEFITS • Single Transverse Mode (TEM 00 ) • OEM or end-user versions • Air- or water-cooled solutions APPLICATIONS • Flow Cytometry • Particle Counting • DNA Sequencing • MicroscopyNext >