< PreviousSuperior Reliability & Performance 108 SPECIFICATIONS 1 Genesis MX-460 Genesis MX-480 Genesis MX-488 Genesis MX-514 Wavelength (nm) 460 ±3 480 ±3488 ±3514 ±3 FWHM Linewidth (GHz)<5 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 500500500, 1000500, 1000 Spatial Mode TEM 00 Beam Quality (M2)<1.1 Beam Circularity 2 1.0 ±0.1 Beam Waist Diameter (mm) (FW, 1/e 2 )1.0 ±0.1 Beam Divergence (mrad) (FW, 1/e 2 ) 0.7 ±0.1 Beam Waist Location 3 (mm) ±0.25 Beam Pointing Stability 4,5 (μrad/°C) <5 Horizontal Beam Position Tolerance 5 (mm) ±<1.0 Vertical Beam Position Tolerance 5 (mm) ±<1.0 Beam Pointing Tolerance 5 (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Vertical, ±5° Noise (%, rms) (10 Hz to 10 MHz)<0.1 Power Stability 6 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes ELECTRICAL SPECIFICATIONS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Non-Operating 10 to 40°C (50 to 104°F) -10 to 60°C (14 to 140°F) Relative Humidity 7 (%) 5 to 95 CE MarkingIEC 61010-1/EN 61010-1 Dimensions (L x W x H) Laser Head 8 Cables (laser head to controller) 281 x 156 x 85 mm (11.06 x 6.14 x 3.35 in.) 2 m (6.5 ft.) 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Circularity defined as vertical diameter divided by horizontal diameter. 3 Negative value corresponds to a location inside head. 4 After 2-hour warm-up. 5 Measured at the output window. 6 Measured over 8 hrs. 7 Non-condensing. 8 Back connector not included in laser head length dimension. Genesis MX SLM-Series Life Sciences Guide Genesis MXcoherent.com 109 SPECIFICATIONS 1 Genesis MX 532 Genesis MX 561 Genesis MX 577 Genesis MX 590 Wavelength (nm) 532 ±3 561 ±3577 ±3590 ±3 FWHM Linewidth (GHz)<5 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 500, 1000500500, 1000500, 1000 Spatial Mode TEM 00 Beam Quality (M2)<1.1 Beam Circularity 2 1.0 ±0.1 Beam Waist Diameter (mm) (FW, 1/e 2 )1.0 ±0.1 Beam Divergence (mrad) (FW, 1/e 2 ) 0.7 ±0.1 Beam Waist Location 3 (mm) ±0.25 Beam Pointing Stability 4,5 (μrad/°C) <5 Horizontal Beam Position Tolerance 5 (mm) ±<1.0 Vertical Beam Position Tolerance 5 (mm) ±<1.0 Beam Pointing Tolerance 5 (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Vertical, ±5° Noise (%, rms) (10 Hz to 10 MHz)<0.1 Power Stability 6 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes ELECTRICAL SPECIFICATIONS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Non-Operating 10 to 40°C (50 to 104°F) -10 to 60°C (14 to 140°F) Relative Humidity 7 (%) 5 to 95 CE MarkingIEC 61010-1/EN 61010-1 Dimensions (L x W x H) Laser Head 8 Cables (laser head to controller) 281 x 156 x 85 mm (11.06 x 6.14 x 3.35 in.) 2 m (6.5 ft.) 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Circularity defined as vertical diameter divided by horizontal diameter. 3 Negative value corresponds to a location inside head. 4 After 2-hour warm-up. 5 Measured at the output window. 6 Measured over 8 hrs. 7 Non-condensing. 8 Back connector not included in laser head length dimension. Life Sciences Guide Genesis MX SLM-Series Genesis MXSuperior Reliability & Performance 110 SPECIFICATIONS 1 Genesis MX 460 OEM Genesis MX 480 OEM Genesis MX 488 OEM Genesis MX 514 OEM Wavelength (nm) 460 ±3480 ±3488 ±3514 ±3 Output Power (mW) 500500500, 1000500, 1000 Spatial Mode TEM 00 FWHM Linewidth (GHz) <30 Pulse FormatCW Beam Circularity1.0 ±0.1 Beam Position Tolerance (mm) Horizontal Vertical ±<1.0 ±<1.0 Beam Waist Diameter (mm) (FW, 1/e 2 ) 1.0 ±0.1 Beam Divergence (mrad) (FW, 1/e 2 )0.7 ±0.1 Beam Waist Location 2,3 (m)±0.25 M2 Horizontal Vertical <1.1 <1.1 Beam Pointing Stability 4 (μrad/°C) <5 Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz 5 (%) (pk-pk) <0.1 <1 Polarization RatioHorizontal, >100:1 CDRH ComplianceNo Warm-up Time (minutes)<10 Direct Modulation 6 Available UTILITY AND ENVIRONMENTAL REQUIREMENTS Operating Diode Current (A) <12.5 <10 <10, <12.5 <10, <12.5 Maximum Diode Current (A) <15 <12<12, <15<12, <15 Diode Voltage (V) 1.5 to 2.2 Cooling Requirements 7 Active cooling required Case Temperature (°C) 25 ±2 Humidity Non-condensing Dimensions (L x W x H) Laser Head 121 x 44 x 65 mm (4.76 x 1.73 x 2.56 in.) Weight Laser Head (g)730 ±10 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Measured at the output of the laser head. 3 Negative value corresponds to a location within the head. 4 Measured at the output window: tolerance relative to the nominal center of the output window and perpendicular to the mounting plane. 5 Over 8 hours. 6 Theoretical limit is >1 MHz; actual performance will be limited by the diode-driver (not included). 7 Contact integration support for options on air-cooling TEC or waterplate. Genesis MX SLM-Series Life Sciences Guide Genesis MXcoherent.com 111 SPECIFICATIONS 1 Genesis MX 532 OEM Genesis MX 561 OEM Genesis MX 577 OEM Genesis MX 590 OEM Wavelength (nm) 532 ±3561 ±3577 ±3590 ±3 Output Power (mW) 500, 1000500500, 1000500, 1000 Spatial Mode TEM 00 FWHM Linewidth (GHz) <5 Pulse FormatCW Beam Circularity1.0 ±0.1 Beam Position Tolerance (mm) Horizontal Vertical ±<1.0 ±<1.0 Beam Waist Diameter (mm) (FW, 1/e 2 ) 1.0 ±0.1 Beam Divergence (mrad) (FW, 1/e 2 )0.7 ±0.1 Beam Waist Location 2,3 (m)±0.25 M2 Horizontal Vertical <1.1 <1.1 Beam Pointing Stability 4 (μrad/°C) <5 Noise 10 Hz to 10 MHz (%) (rms) 10 Hz to 5 kHz 5 (%) (pk-pk) <0.1 <1 Polarization RatioHorizontal, >100:1 CDRH ComplianceNo Warm-up Time (minutes)<10 Direct Modulation 6 Available UTILITY AND ENVIRONMENTAL REQUIREMENTS Operating Diode Current (A) <10, <12.5<10 <10, <12.5 <10, <12.5 Maximum Diode Current (A) <12, <15<12<12, <15<12, <15 Diode Voltage (V) 1.5 to 2.2 Cooling Requirements 7 Active cooling required Case Temperature (°C) 25 ±2 Humidity Non-condensing Dimensions (L x W x H) Laser Head 121 x 44 x 65 mm (4.76 x 1.73 x 2.56 in.) Weight Laser Head (g)730 ±10 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Measured at the output of the laser head. 3 Negative value corresponds to a location within the head. 4 Measured at the output window: tolerance relative to the nominal center of the output window and perpendicular to the mounting plane. 5 Over 8 hours. 6 Theoretical limit is >1 MHz; actual performance will be limited by the diode-driver (not included). 7 Contact integration support for options on air-cooling TEC or waterplate. Life Sciences Guide Genesis MX SLM-Series Genesis MXSuperior Reliability & Performance 112 MECHANICAL SPECIFICATIONS 78.74 mm (3.1 in.) 200.86 mm (7.91 in.) 219.91 mm (8.66 in.) 67.26 mm (2.65 in.) 61.6 mm (2.43 in.) 13.53 mm (0.53 in.) 10.41 mm (0.41 in.) 10.0 mm (0.39 in.) 0.0 mm(0.0 in.) 36.96 mm (1.45 in.) 53.96 mm (2.12 in.) 165.96 mm (6.53 in.) 182.96 mm (7.20 in.) Mounting Holes M5 - 0.8 X 0.38 in. Deep (4X) Mounting Holes 10-32 X 0.38 in. Deep (4X) Alignment Slot 0.251/0.252 in. Wide X 0.25 in. Long X 0.38 in. Deep Alignment Hole 0.251/0.252 in. Dia. X 0.38 in. Deep 61.6 mm (2.43 in.) 55.0 mm (2.17 in.) 45.0 mm (1.77 in.) M5 M5 M5 M5 10-32 10-32 10-32 10-32 68.2 mm (2.69 in.) 47.64 mm (1.88 in.) 89.22 mm (3.51 in.) Front View Top View Side View Rear View Genesis MX SLM-Series (End-User) Air-cooled version Genesis MX SLM-Series (End-User) Water-cooled version 78.74 mm (3.1 in.) 61.6 mm (2.43 in.) 200.86 mm (7.91 in.) 219.91 mm (8.66 in.) 21.29 mm (0.84 in.) 13.53 mm (0.53 in.) 10.41 mm (0.41 in.) 10.0 mm (0.39 in.) 0.0 mm (0.0 in.) 36.96 mm (1.45 in.) 53.96 mm (2.12 in.) 165.96 mm (6.53 in.) 182.96 mm (7.20 in.) Mounting Holes M5 - 0.8 X 0.38 in. Deep (4X) Mounting Holes 10-32 X 0.38 in. Deep (4X) Alignment Slot 0.251/0.252 in. Wide X 0.25 in. Long X 0.38 in. Deep Alignment Hole 0.251/0.252 in. Dia. X 0.38 in. Deep 61.6 mm (2.43 in.) 55.0 mm (2.17 in.) 45.0 mm (1.77 in.) M5 M5 M5 M5 10-32 10-32 10-32 10-32 68.2 mm (2.69 in.) 47.64 mm (1.88 in.) 89.22 mm (3.51 in.) Front View Top View Side View Rear View Genesis MX SLM-Series Life Sciences Guide Genesis MXcoherent.com 113 MECHANICAL SPECIFICATIONS Slot 3.2 +0.025/-0.0 mm (0.126 + 0.001/-0.0 in.) Wide X 2.03 mm (0.08 in.) Long X 5.08 mm (0.20 in.) Deep Mounting Holes M3 X 12.2 mm (0.48 in.) Deep (4X) 3.2 +0.025/-0.0 mm (0.126 + 0.001/-0.0 in.) DIA X 5.08 mm (0.20 in.) Deep 5.46 mm (0.22 in.) 120.65 mm (4.75 in.) 111.1 mm (4.37 in.) 34.55 mm (1.36 in.) 4.78 mm (0.19 in.) 61 mm (2.4 in.) 34 mm (1.34 in.) 17 mm (0.67 in.) 22 mm (0.87 in.) 44 mm (1.73 in.) 26 mm (1.02 in.) 29.78 mm (1.17 in.) 28.15 mm (1.11 in.) 18.8 mm (0.74 in.) 18.8 mm (0.74 in.) 24.89 mm (0.98 in.) 6.1 mm (0.24 in.) 5.08 mm (0.2 in.) 45.21 mm (1.78 in.) 6.35 mm (0.25 in.) 6.35 mm (0.25 in.) 6.35 mm (0.25 in.) 5.08 mm (0.2 in.) 16.26 mm (0.64 in.) Spacer Detail Clamping Bar Detail 3.175 mm (0.125 in.) 1.52 mm (0.06 in.) 12.95 mm (0.51 in.) 4.06 mm (0.16 in.) 86.87 mm (3.42 in.) 89.92 mm (3.54 in.) 112.78 mm (4.44 in.) 112.78 mm (4.44 in.) 120.65 mm (4.75 in.) 11.43 mm (0.45 in.) 53.59 mm (2.11 in.) 12.7 mm (0.5 in.) 15.24 mm (0.6 in.) 8-32 UNC-2B X 0.50 Deep (4X) 0.125 Dia. Dowel Pin (2X) 0.188 Dia. Thru (2X) This surface must be flat within 0.001 in. and have 32 µm finish or better within TEC mounting areas. Base Plate Requirements Front View Top View Rear View Side View Genesis MX SLM-Series (OEM) Water-cooled version Genesis MX SLM-Series Benchtop Power Supply 159.8 mm (6.29 in.) 19.8 mm (0.78 in.) 361.1 mm (14.22 in.) 228.9 mm (9.01 in.) Side ViewFront View Life Sciences Guide Genesis MX SLM-Series Genesis MXSuperior Reliability & Performance 114 MECHANICAL SPECIFICATIONS 16.0 mm (0.63 in.) 16.0 mm (0.63 in.) 15.24 mm (0.6 in.) 127 mm (5.0 in.) 22.43 mm (0.88 in.) 18.34 mm (0.72 in.) 77.65 mm (3.06 in.) 42.15 mm (1.66 in.) 111.76 mm (4.4 in.) 111.0 mm (4.37 in.) 15.24 mm (0.60 in.) M36-32 6-32 6-32 6-32 M3 M3 M3 M3 6-326-32 6-32 M3M3 M3 0 mm (0.0 in.) RS-232D Serial Port USB Interlock 24V In 127 mm (5.0 in.) 257.15 mm (10.12 in.) 0 mm (0.0 in.) 0 mm (0.0 in.) 52.37 mm (2.06 in.) 68.58 mm (2.70 in.) 243.31 mm (9.58 in.) 204.77 mm (8.06 in.) 188.57 mm (7.42 in.) 52.37 mm(2.06 in.)68.58 mm(2.70 in.) 204.77 mm(8.06 in.)188.57 mm(7.42 in.) 111 mm (4.37 in.) 111.76 mm (4.40 in.) Mounting Holes 10X On Bottom As Indicated Mounting Holes (both sides) GND Diode Out Laser Control TEC Ext. Fan Front View Rear View Top View Side View Bottom View Genesis MX SLM-Series Low Current OEM Controller Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Genesis MX SLM lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative. ISO 9001 Registered Genesis MX SLM-Series Life Sciences Guide Genesis MXcoherent.com 115 Genesis CX Genesis CX STM-Series High Performance High Power UV and Visible OPS Laser Systems Based on Coherent’s Optically Pumped Semiconductor Laser (OPSL) technology, the Genesis CX STM laser is a high-performance CW TEM 00 laser providing up to 10 W in the visible wavelength range (460 nm to 590 nm) and up to 250 mW in the UV (355 nm). Standard wavelengths and powers include: - 355 nm, at up to 250 mW - 460, 480, 488, 514, 532, 561, 577, and 590 nm, at up to 10 W OPSL technology furthermore offers the unique ability to tailor the wavelength of the laser to meet your unique applications requirement, limited only by the semiconductor material system being used. Current capabilities include 310 to 390 nm, 460 to 590 nm, and 920 to 1180 nm, with new wavelengths under development. FEATURES & BENEFITS • Up to 10 W output power at visible wavelengths • Up to 250 mW output power at UV wavelengths • Standard wavelengths at 355, 460, 480, 488, 514, 532, 561, 577, and 590 nm • Superior mode quality • Power-invariant beam properties • Low noise • PermAlign™ solder-bonded optics technology • AAA™ ultra-long life pump diodes • OEM and end-user configuration options APPLICATIONS • Semiconductor Inspection • Semiconductor Mask Writing • Flow Cytometry • DNA Sequencing • Particle Counting • Confocal Microscopy • Particle Image VelocimetrySuperior Reliability & Performance 116 Genesis CX STM-Series Life Sciences Guide Genesis CX SPECIFICATIONS 1 Genesis CX-355 2 Wavelength (nm) 355 ±2 FWHM Linewidth (GHz) <50 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 40, 60, 80, 100, 150, 200, 250 Power Tunability 3 5 mW to 100% full rated power Spatial Mode TEM 00 Beam Quality (M2) <1.2 Beam Circularity 4 1.0 ±0.1 Beam Waist Diameter (mm) (FW, 1/e 2 )0.975 ±0.2 Beam Divergence (mrad) (FW, 1/e 2 ) <1.2 Beam Waist Location 5 (m) ±0.325 Beam Position Stability 6 (μm/°C)<5 Beam Pointing Stability 6 (μrad/°C) <6 Beam Position Tolerance 7 (mm) Horizontal Vertical ±<1.0 ±<1.0 Beam Pointing Tolerance (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Vertical 10 , ±5° Noise (%, rms) (10 Hz to 1 MHz) <0.1 Power Stability 8 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes UTILITY REQUIREMENTS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 11 Cooling Requirements for ambient temperatures up to 35°C for ambient temperatures up to 40°C for Genesis CX-532 10 W Laser Heat sink required Genesis CX Air-Cooled Riser, Genesis CX Water-Cooled Riser or equivalent Genesis CX Water-Cooled Riser or equivalent Genesis CX Water-Cooled Riser or equivalent ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Condition Non-Operating Condition 10 to 40°C (50 to 104°F) non-condensing -10 to 60°C (14 to 140°F) Relative Humidity 9 (%)5 to 95 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Available in OEM or end user versions. 3 Noise specification applies at full rated power. Noise varies roughly inversely proportionally to the out power. 4 Circularity defined as vertical diameter divided by horizontal diameter. 5 Negative value corresponds to a location inside head. 6 After warm-up over 2 hours. 7 Measured at the output window. Positions are relative to the base and side of the laser as shown in the drawing. 8 Measured over 8 hours. 9 Non-condensing. 10 Vertical + normal to laser base plane. 11 Power consumption for the CX 355-250 is 600 W.coherent.com 117 Life Sciences Guide Genesis CX STM-Series Genesis CX SPECIFICATIONS 1 Genesis CX-460 2 Genesis CX-480 2 Genesis CX-488 2 Genesis CX-514 2 Wavelength (nm) 460 ±3 480 ±3488 ±3514 ±3 FWHM Linewidth (GHz) <30 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 10001000, 2000, 3000 1000, 2000, 3000, 4000 2000, 4000 Power Tunability 3 50 mW to 100% full rated power Spatial Mode TEM 00 Beam Quality (M2) <1.1 Beam Circularity 4 1.0 ±0.1 Beam Waist Diameter (mm) (FW, 1/e 2 )2.1 ±0.32.1 ±0.32.2 ±0.32.2 ±0.3 Beam Divergence (mrad) (FW, 1/e 2 ) <0.5 Beam Waist Location 5 (m) ±0.5 Beam Position Stability 6 (μm/°C)<5 Beam Pointing Stability 6 (μrad/°C) <5 Beam Position Tolerance 7 (mm) Horizontal Vertical ±<1.0 ±<1.0 Beam Pointing Tolerance (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Horizontal, ±5° Noise (%, rms) (10 Hz to 10 MHz) <0.1 Power Stability 8 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes UTILITY REQUIREMENTS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 Cooling Requirements for ambient temperatures up to 35°C for ambient temperatures up to 40°C for Genesis CX-532 10 W Laser Heat sink required Genesis CX Air-Cooled Riser, Genesis CX Water-Cooled Riser or equivalent Genesis CX Water-Cooled Riser or equivalent Genesis CX Water-Cooled Riser or equivalent ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Condition Non-Operating Condition 10 to 40°C (50 to 104°F) non-condensing -10 to 60°C (14 to 140°F) Relative Humidity 9 (%)5 to 95 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Available in OEM or end user versions. 3 Noise specification applies at full rated power. Noise varies roughly inversely proportionally to the out power. 4 Circularity defined as vertical diameter divided by horizontal diameter. 5 Negative value corresponds to a location inside head. 6 After warm-up over 2 hours. 7 Measured at the output window. Positions are relative to the base and side of the laser as shown in the drawing. 8 Measured over 8 hours. 9 Non-condensing.Next >