< PreviousSuperior Reliability & Performance 118 Genesis CX STM-Series Life Sciences Guide Genesis CX SPECIFICATIONS 1 Genesis CX-532 2 Genesis CX-532 2 Genesis CX-561 2 Genesis CX-577 2 Genesis CX-589/590 2 Wavelength (nm) 532 ±3532 ±3561 ±3577 ±3590 ±3 FWHM Linewidth (GHz) <30 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 2000, 4000, 5000, 6000, 7000, 8000 10,00030001000, 2000, 3000 2000, 3000 Power Tunability 3 50 mW to 100% full rated power Spatial Mode TEM 00 Beam Quality (M2) <1.1 Beam Circularity 4 1.0 ±0.1 Beam Waist Diameter (mm) (FW, 1/e 2 )2.3 ±0.32.3 ±0.32.3 ±0.32.3 ±0.32.4 ±0.3 Beam Divergence (mrad) (FW, 1/e 2 ) <0.5 Beam Waist Location 5 (m) ±0.5 Beam Position Stability 6 (μm/°C)<5 Beam Pointing Stability 6 (μrad/°C) <5 Beam Position Tolerance 7 (mm) Horizontal Vertical ±<1.0 ±<1.0 Beam Pointing Tolerance (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Horizontal, ±5° Noise (%, rms) (10 Hz to 1 MHz) <0.1 Power Stability 8 (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes UTILITY REQUIREMENTS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 Cooling Requirements for ambient temperatures up to 35°C for ambient temperatures up to 40°C for Genesis CX-532 10 W Laser Heat sink required Genesis CX Air-Cooled Riser, Genesis CX Water-Cooled Riser or equivalent Genesis CX Water-Cooled Riser or equivalent Genesis CX Water-Cooled Riser or equivalent ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Condition Non-Operating Condition 10 to 40°C (50 to 104°F) non-condensing -10 to 60°C (14 to 140°F) Relative Humidity 9 (%)5 to 95 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Available in OEM or end user versions. 3 Noise specification applies at full rated power. Noise varies roughly inversely proportionally to the out power. 4 Circularity defined as vertical diameter divided by horizontal diameter. 5 Negative value corresponds to a location inside head. 6 After warm-up over 2 hours. 7 Measured at the output window. Positions are relative to the base and side of the laser as shown in the drawing. 8 Measured over 8 hours. 9 Non-condensing. 10 Vertical + normal to laser base plane.coherent.com 119 Life Sciences Guide Genesis CX STM-Series Genesis CX MECHANICAL SPECIFICATIONS Dimensions (L x W x H) Laser Head 1 Laser Head, 532-10000 Power Supply (End User) Power Supply (OEM) Cables (laser head to controller) 281 x 156 x 85 mm (11.06 x 6.14 x 3.35 in.) 281 x 156 x 87 mm (11.1 x 6.1 x 3.4 in.) 361 x 229 x 180 mm (14.2 x 9.0 x 7.1 in.) 300 x 208 x 97 mm (11.8 x 8.2 x 3.8 in.) 3 m (9.8 ft.) Weight Laser Head Laser Head, 532-10000 Power Supply (End User) Power Supply (OEM) 7.1 kg (15.65 lbs) 8.6 kg (18.96 lbs) 6.0 kg (13.23 lbs) 3.8 kg (8.38 lbs) CE MarkingIEC 61010-1/EN 61010-1 1 Back connector not included in laser head length dimension. MECHANICAL SPECIFICATIONS Genesis CX STM-Series Head OEM and End User Models (except 532-10000) 19.38 mm (0.76 in.) 80 mm (3.15 in.) 144.93 mm (5.71 in.) 156.06 mm (6.14 in.) 5.56 mm (0.22 in.) 280.57 mm (11.05 in.) 182.88 mm (7.2 in.) 108.9 mm (4.29 in.) 34.93 mm (1.38 in.) 20.65 mm (0.81 in.) 133.38 mm (5.25 in.) 0.0 mm (0.0 in.) 47.28 mm (1.86 in.) 165.38 mm (6.51 in.) 10.0 mm (0.39 in.) 4.78 mm Dia. Thru C’Bore 7.92 mm Dia. X 4.83 mm Deep (0.188 Dia. Thru C’Bore 0.312 in. Dia. X 0.19 in. Deep) (6X) 137.26 mm (5.4 in.) 280.67 mm (11.05 in.) 280.67 mm (11.05 in.) 127 mm (5.0 in.) Power On Indicator Manual Shutter 11.94 mm (0.47 in.) Slot 6.38 +0.03/-0.00 mm Wide X 9.7 mm Deep (0.251 +0.001/-0.00 in. Wide X 0.38 in. Deep 6.38 +0.03/-0.00 mm Dia. X 9.7 mm Deep (0.251 +0.001/-0.00 in. Dia. X 0.38 in. Deep 52.85 mm (2.08 in.) 44.75 mm (1.76 in.) 84.51 mm (3.33 in.) 156.06 mm (6.14 in.) Output Beam Heatsink Surface Fan Aux. Control DC Power Ground Lug Min. Bend Radius Top View Side View Bottom View Rear View Front ViewSuperior Reliability & Performance 120 Genesis CX STM-Series Life Sciences Guide Genesis CX MECHANICAL SPECIFICATIONS Genesis CX STM-Series Head 532-10000 52.85 mm (2.08 in.) 27.0 mm (1.06 in.) 41.28 mm (1.63 in.) 147.32 mm (5.8 in.) 10.0 mm (0.39 in.) 26.97 mm (1.06 in.) 6.375 mm (0.251 in.) Dia. x 7.92 mm (0.31 in.) Deep Alignment Pin Hole 6.375 mm (0.251 in.) Wide x 7.92 mm (0.31 in.) Deep Alignment Pin Slot 4.78 mm (0.188 in.) Dia. Mounting Screw Holes 6 Places Cooling Surface 2.03 mm (0.08 in.) 221.77 mm (8.73 in.) 280.57 mm (11.05 in.) 189.23 mm (7.45 in.) 139.73 mm (5.5 in.) 115.25 mm (4.54 in.) 9.53 mm (0.38 in.) 5.56 mm (0.22 in.) 52.85 mm (2.08 in.) 156.06 mm (6.14 in.) 44.75 mm (1.76 in.) 87.12 mm (3.43 in.) Shutter Power Indicator Lamp Output Beam Ground DC Power In Control Bottom View Front View Top View Side ViewRear View Genesis CX-Series Benchtop Power Supply 159.8 mm (6.29 in.) 19.8 mm (0.78 in.) 361.1 mm (14.22 in.) 228.9 mm (9.01 in.) Side ViewFront Viewcoherent.com 121 Life Sciences Guide Genesis CX STM-Series Genesis CX 208.28 mm (8.2 in.) 96.52 mm (3.8 in.) 299.72 mm (11.8 in.) MECHANICAL SPECIFICATIONS Genesis CX-Series High Current OEM Power Supply Front ViewRear View Top View Side View Bottom ViewSuperior Reliability & Performance 122 Genesis CX STM-Series Life Sciences Guide Genesis CX MECHANICAL SPECIFICATIONS Genesis CX STM-Series Air-Cooled Riser 280.6 mm (11.05 in.) 292.1 mm (11.5 in.) Aux Output Beam Power On Indicator Manual Shutter Control DC Power Ground Lug Fan Cooling Air Cooling Air Mounting Holes 6.73 mm (0.265 in.) Diameter Thru (6X) 137.0 mm (5.39 in.) 12.2 mm (0.48 in.) 12.5 mm (0.49 in.) 18.6 mm (0.73 in.) 18.6 mm (0.73 in.) 138.3 mm (5.44 in.) 178.1 mm (7.01 in.) 138.3 mm (5.44 in.) 56.8 mm (2.24 in.) 164.0 mm (6.46 in.) 76.2 mm (3.0 in.) 152.4 mm (6.0 in.) 5.8 mm (0.23 in.) 6.4 mm (0.25 in.) 6.4 mm (0.25 in.) Top View Bottom View Rear View Side View Front Viewcoherent.com 123 Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Genesis CX STM lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative. ISO 9001 Registered Life Sciences Guide Genesis CX STM-Series Genesis CX MECHANICAL SPECIFICATIONS Genesis CX STM-Series Water-Cooled Riser 280.6 mm (11.05 in.) 228.6 mm (9.0 in.) 203.2 mm (8.0 in.) Aux Output Beam Power On Indicator Manual Shutter Control DC Power Ground Lug Cooling Water Fittings 7.92 mm (0.31 in.) Wide Slots (4X) 84.5 mm (3.33 in.) 12.7 mm (0.5 in.) 5.4 mm (0.21 in.) 87.6 mm (3.45 in.) 43.5 mm (1.71 in.) 9.4 mm (0.37 in.) 160.2 mm (6.31 in.) 120.4 mm (4.74 in.) 156.1 mm (6.14 in.) 52.9 mm (2.08 in.) 144.7 mm (5.7 in.) 97.1 mm (3.82 in.) 52.9 mm (2.08 in.) 59.0 mm (2.32 in.) 11.4 mm (0.45 in.) 12.7 mm (0.5 in.) 137.3 mm (5.4 in.) 120.4 mm (4.74 in.) 44.8 mm (1.76 in.) Top View Bottom View Rear View Side View Front ViewSuperior Reliability & Performance 124 Genesis CX 355 STM Compact (OEM) TEM 00 355 nm OEM OPS Laser Systems Coherent’s unique Optically Pumped Semiconductor Laser (OPSL) technology powers the Genesis CX-STM Compact, providing up to 100 mW of 355 nm laser light from an OEM system. Ideal for applications such as Flow Cytometery and Particle Counting, these lasers provide a TEM00 power invariant beam with low noise and high stability in a simple-to-integrate, air-cooled package. The Genesis CX STM Compact is the perfect laser platform for customers requiring easy integration of high-performing CW laser technology into life science and bioinstrumentation. FEATURES & BENEFITS • Single Transverse Mode (TEM 00 ) • Reduced sized OEM • Air-cooled solution APPLICATIONS • Flow Cytometry • Particle Counting • Microscopy Genesis CXcoherent.com 125 SPECIFICATIONS 1 Genesis CX-355 Wavelength (nm) 355 ±2 FWHM Linewidth (GHz) <50 Pulse Format CW Spectral Purity (%) >99 Output Power (mW) 40, 60, 80, 100 Spatial Mode TEM 00 Beam Quality (M2) <1.2 Beam Circularity 2 1.0 ±0.1 Beam Waist Diameter (mm) (FW, 1/e 2 ) Horizontal Vertical 0.975 ±0.2 0.915 ±0.2 Beam Divergence (mrad) (FW, 1/e 2 ) <1.2 Beam Waist Location 3 (mm) ±325 Beam Pointing Stability 4 (μrad/°C) <6 Horizontal Beam Position Tolerance (mm) ±<1.0 Vertical Beam Position Tolerance (mm) ±<1.0 Beam Pointing Tolerance (mrad) <5 Polarization Ratio Linear, >100:1 Polarization Direction Horizontal, ±5° Noise (%, rms) (10 Hz to 1 MHz) <0.1 Power Stability (%) (pk-pk) ±<1 Warm-up Time (minutes) <10 CDRH Compliant Yes ELECTRICAL SPECIFICATIONS Operating Voltage (VAC)100 to 240 Frequency (Hz)50 to 60 Power Consumption (W)500 9 ENVIRONMENTAL CONDITIONS Ambient Temperature Operating Condition Non-Operating Condition 10 to 40°C (50 to 104°F) non-condensing -10 to 60°C (14 to 140°F) Relative Humidity 5 (%) 5 to 95 CE MarkingIEC 61010-1/EN 61010-1 Dimensions (L x W x H) Laser Head 6 Cables (laser head to controller) 250.1 x 138.0 x 50.8 mm (9.84 x 5.4 x 2.0 in.) 2 m (6.5 ft.) 1 Optical parameters measured at the output plane of the laser head. Unless noted all parameters valid for the lifetime of the unit. 2 Circularity defined as vertical diameter divided by horizontal diameter. 3 Negative value corresponds to a location inside head. 4 After warm-up over 2 hours. 5 Non-condensing. 6 Back connector not included in laser head length dimension. Life Sciences Guide Genesis CX 355 STM Compact (OEM) Genesis CXSuperior Reliability & Performance 126 MECHANICAL SPECIFICATIONS 204.77 mm (8.06 in.) 188.57 mm (7.42 in.) 68.58 mm (2.70 in.) 52.37 mm (2.06 in.) 127.0 mm (5.0 in.) 21.16 mm (0.833 in.) 204.77 mm (8.06 in.) 188.57 mm (7.42 in.) 269.85 mm (10.62 in.) 260.78 mm (10.27 in.) 68.58 mm (2.70 in.) 52.37 mm (2.06 in.) 24V IN RS232D SERIAL PORT INTERLOCK USB 1 0 42.16 mm (1.66 in.) 111.76 mm (4.40 in.) 111.76 mm (4.40 in.) 111.0 mm (4.37 in.) 16.0 mm (0.63 in.) 111.0 mm (4.37 in.) 77.65 mm (3.06 in.) 18.34 mm (0.72 in.) 0 MOUNTING HOLES ARE BOTH NEAR AND FARSIDE 0 0 GND DIODE OUT USB 2 0 .600 .630 0 15.24 mm (0.60 in.) 0 MOUNTING HOLES (BOTTOM) 6-326-32M3M3 6-326-32 6-32 6-32 M3M3 M3 M3 6-32 Front View Rear View Side View Top View 2-M4 4-M4 Mounting Hole Name plate CN1 Output voltage adjustable potentiometer LED Terminal cover CN2 CN3 Name plate M4 M4 Output terminal( + ) Output terminal( - ) AC(N) AC(L) AIR FLOW xam6071 50.5 102 42 (14) (15.5) 8.6 (23.5) 25max (87) (30) 28.564 ± 0.5 (6) 10 7 (50) 12 12 20 ± 0.5 5474 ± 0.5 (75) 12 FG() Mounting Hole (Bottom sides) H V.ADJ Top View Rear View Side View Front View Bottom View Genesis CX Compact Controller Genesis CX-Series Optional AC/DC Power Supply Genesis CX 355 STM Compact (OEM) Life Sciences Guide Genesis CXcoherent.com 127 MECHANICAL SPECIFICATIONS Genesis CX 355 STM Compact (OEM) 287.32 mm (11.31 in.) 138.33 mm (5.446 in.) OUTPUT BEAM 95.38 mm (3.755 in.) 20.96 mm (0.825 in.) 110.74 mm (4.36 in.) 234.19 mm (9.22 in.) 50.75 mm (2.0 in.) 7.95 mm (0.31 in.) 31.75 mm (1.25 in.) 9.53 mm (0.375 in.) 30.15 mm (1.19 in.) Side View Top View Rear ViewFront View Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Genesis CX-Series lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative. ISO 9001 Registered Life Sciences Guide Genesis CX 355 STM Compact (OEM) Genesis CXNext >